Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

Filters

My NCBI Filters

Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
1976 1
2005 1
2006 1
2011 1
2013 2
2015 1
2017 1
2021 2
2024 0

Text availability

Article attribute

Article type

Publication date

Search Results

9 results

Results by year

Filters applied: . Clear all
Page 1
Direct comparison of nanoindentation and macroscopic measurements of bone viscoelasticity.
Shepherd TN, Zhang J, Ovaert TC, Roeder RK, Niebur GL. Shepherd TN, et al. J Mech Behav Biomed Mater. 2011 Nov;4(8):2055-62. doi: 10.1016/j.jmbbm.2011.07.004. Epub 2011 Jul 18. J Mech Behav Biomed Mater. 2011. PMID: 22098905 Free PMC article.
Initially, dogbone samples were prepared and subjected to torsional stress relaxation in a saline bath at 37 C. A 5 mm thick disk was subsequently sectioned from the gage length, and subjected to nanoindentation. Nanoindentation was performed on hydrated samples using a st …
Initially, dogbone samples were prepared and subjected to torsional stress relaxation in a saline bath at 37 C. A 5 mm thick disk was subseq …
Linear Friction Welding of an AZ91 Magnesium Alloy and the Effect of Ca Additions on the Weld Characteristics.
Villegas-Armenta LA, Wanjara P, Gholipour J, Nakatsugawa I, Chino Y, Pekguleryuz M. Villegas-Armenta LA, et al. Materials (Basel). 2021 Jun 7;14(11):3130. doi: 10.3390/ma14113130. Materials (Basel). 2021. PMID: 34200334 Free PMC article.
These microstructural changes in the AZ91/AZ91 and AZ91-2Ca/AZ91-2Ca joints increased the hardness in the weld zone by 32%. The use of digital image correlation for strain mapping along the sample gage length during tensile testing revealed that the local strains we …
These microstructural changes in the AZ91/AZ91 and AZ91-2Ca/AZ91-2Ca joints increased the hardness in the weld zone by 32%. The use o …
Determination of peak deflections from human surrogates using chestbands in side impact tests.
Yoganandan N, Humm JR, Pintar FA, Maiman DJ. Yoganandan N, et al. Med Eng Phys. 2013 Aug;35(8):1181-7. doi: 10.1016/j.medengphy.2012.12.012. Epub 2013 Jan 26. Med Eng Phys. 2013. PMID: 23357337
The oblique load-wall fixed to the sled consisted of separate and adjustable plates to contact the shoulder, thorax, abdomen, and pelvis. Two 59-gage chestbands were wrapped on the thorax and abdomen. Tests were conducted at low, medium, and high velocities (3.4, 6.7, and …
The oblique load-wall fixed to the sled consisted of separate and adjustable plates to contact the shoulder, thorax, abdomen, and pelvis. Tw …
The effect of fiber orientation on the polymerization shrinkage strain of fiber-reinforced composites.
Tezvergil A, Lassila LV, Vallittu PK. Tezvergil A, et al. Dent Mater. 2006 Jul;22(7):610-6. doi: 10.1016/j.dental.2005.05.017. Epub 2005 Oct 18. Dent Mater. 2006. PMID: 16239026
As control materials, particulate filler composite resin and unfilled dimethacrylate monomer resin were used. Two uniaxial strain gages (gage length 2mm) were used to measure shrinkage strains in two directions: longitudinally and transversally to the fiber direction. ...
As control materials, particulate filler composite resin and unfilled dimethacrylate monomer resin were used. Two uniaxial strain gages ( …
Insilico molecular modeling, docking and spectroscopic [FT-IR/FT-Raman/UV/NMR] analysis of Chlorfenson using computational calculations.
Ramalingam S, Periandy S, Sugunakala S, Prabhu T, Bououdina M. Ramalingam S, et al. Spectrochim Acta A Mol Biomol Spectrosc. 2013 Nov;115:118-35. doi: 10.1016/j.saa.2013.06.034. Epub 2013 Jun 18. Spectrochim Acta A Mol Biomol Spectrosc. 2013. PMID: 23832220
Moreover, (13)C NMR and (1)H NMR chemical shifts are calculated by using the gage independent atomic orbital (GIAO) technique with HF/B3LYP/B3PW91 methods on same basis set. ...
Moreover, (13)C NMR and (1)H NMR chemical shifts are calculated by using the gage independent atomic orbital (GIAO) technique with HF …
Mechanical evaluation of newly developed mouthpiece using polyethylene terephthalate glycol for transoral robotic surgery.
Fujiwara K, Fukuhara T, Niimi K, Sato T, Kataoka H, Kitano H, Takeuchi H. Fujiwara K, et al. J Robot Surg. 2015 Dec;9(4):347-54. doi: 10.1007/s11701-015-0539-7. Epub 2015 Nov 4. J Robot Surg. 2015. PMID: 26530849 Free PMC article.
The rod was pressed against the tooth model outfitted with two types of mouthpiece and the dynamic load was measured with a load cell and the strain with a strain gage. The maximum dynamic load was 1.29 0.03 kgf for the PETG mouthpiece and 2.24 0.05 kgf for the EVA mouthpi …
The rod was pressed against the tooth model outfitted with two types of mouthpiece and the dynamic load was measured with a load cell and th …
Deformation and fatigue of tough 3D printed elastomer scaffolds processed by fused deposition modeling and continuous liquid interface production.
Miller AT, Safranski DL, Wood C, Guldberg RE, Gall K. Miller AT, et al. J Mech Behav Biomed Mater. 2017 Nov;75:1-13. doi: 10.1016/j.jmbbm.2017.06.038. Epub 2017 Jul 1. J Mech Behav Biomed Mater. 2017. PMID: 28689135
Despite the slight difference in local architecture and tolerances, crosslinked PU solid samples were found to perform on par with PCU solid samples in tensile fatigue, when appropriately adjusted for material hardness. Finally, tests of samples with printed architecture l …
Despite the slight difference in local architecture and tolerances, crosslinked PU solid samples were found to perform on par with PCU solid …